Computerised industrial sewing machines show a code on the panel when the control box detects a problem. Pick your brand and code. Each page explains, in plain words, what the machine has detected, what to check first, and which parts are usually involved, with the manual it was read from.
| E007 | Motor overload | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E011 | External media not inserted | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E012 | Read error on external media | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E013 | Write error on external media | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E015 | Sewing area exceeded | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E016 | External media full | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E019 | File size over | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E032 | File not compatible | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E302 | Machine head tilt detected | 910N, AMS-210E, AMS-210EN, AMS-221EN, DDL-8700B… |
| E303 | Main shaft Z-phase sensor error | 910N, AMS-210E, AMS-251, APW-895N, APW-896N… |
| E703 | Panel connected to the wrong machine | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E704 | System version mismatch | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E730 | Motor encoder error (A/B phase) | 910N, AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN… |
| E731 | Motor encoder error (U/V/W) | 910N, AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN… |
| E733 | Main motor turning the wrong way | 210E, AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN… |
| E811 | Over-voltage | 210E, 910N, AMS-210E, AMS-210EN, AMS-221EN… |
| E813 | Low voltage | 210E, 910N, AMS-210E, AMS-210EN, AMS-221EN… |
| E903 | Pulse-motor power (+85 V) missing | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E904 | Solenoid power (+33 V) missing | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E915 | Panel – MAIN board communication error | 210E, AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN… |
| E916 | MAIN – SDC board communication error | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
| E943 | MAIN board EEPROM write error | AMS-210E, AMS-210EN, AMS-221EN, AMS-224EN, AMS-251… |
We are adding codes from more manuals every week. Send the code and the machine model on WhatsApp +91-9643480908, or request a repair.
Switch the machine off, wait ten seconds and switch it on again. If the code returns, find it below: each page says what the control box has detected and what to check, in the order the maker’s manual suggests.
Each explanation is written by us after reading the manufacturer’s instruction or service manual, and names the manual and page. For the full procedure, use the manual; for a visit or a board repair, use our repair form.
Yes. Shankar Sewing repairs sewing machine PCBs and control boxes and supplies servo motors, boards and sensors. Send the error code and your machine model on WhatsApp (+91-9643480908) or through the repair form.